Study of various leads present in different lobes.
Study of various leads present in different lobes.
1. For Prefrontal Lobe
STEP 1 : Make all the Correct Connections.
1. Connect Fp1 lead point of human brain to the positive terminal (Fp1) of first op-amp circuit.
2. Connect Fp2 lead point of human brain to the positive terminal (Fp2) of second op-amp circuit.
3. Connect Ground lead point A1 of human brain to the negative terminal (A1) of op-amp circuit.
4. Connect Ground lead point A2 of human brain to the negative terminal (A2) of op-amp circuit.
STEP 2 : Click on check button to check for Correct Connections.
STEP 3 : If Connections are not correct click on reset button for reset connections.
STEP 4 : If Connections are correct click on play/pause button to see recorded eeg signals for Fp1 and Fp2.
STEP 5 : Click on waveform tab for data obsevation and measurement.
STEP 6 : Click on print button to save the observations.
2. For Frontal Lobe
STEP 1 : Make all the Correct Connections.
1. Connect F7 lead point of human brain to the positive terminal (F7) of first op-amp circuit.
2. Connect F3 lead point of human brain to the positive terminal (F3) of second op-amp circuit.
3. Connect Fz lead point of human brain to the positive terminal (Fz) of third op-amp circuit.
4. Connect F4 lead point of human brain to the positive terminal (F4) of fourth op-amp circuit.
5. Connect F8 lead point of human brain to the positive terminal (F8) of fifth op-amp circuit.
6. Connect Ground lead point A1 of human brain to the negative terminal (A1) of op-amp circuit.
7. Connect Ground lead point A2 of human brain to the negative terminal (A2) of op-amp circuit.
STEP 2 : Click on check button to check for Correct Connections.
STEP 3 : If Connections are not correct click on reset button for reset connections.
STEP 4 : If Connections are correct click on play/pause button to see recorded eeg signals for Fp1 and Fp2.
STEP 5 : Click on waveform tab for data obsevation and measurement.
STEP 6 : Click on print button to save the observations.
3. For Temporal Lobe
STEP 1 : Make all the Correct Connections.
1. Connect T3 lead point of human brain to the positive terminal (T3) of first op-amp circuit.
2. Connect T5 lead point of human brain to the positive terminal (T5) of second op-amp circuit.
3. Connect T4 lead point of human brain to the positive terminal (T4) of third op-amp circuit.
4. Connect T6 lead point of human brain to the positive terminal (T6) of fourth op-amp circuit.
5. Connect Ground lead point A1 of human brain to the negative terminal (A1) of op-amp circuit.
6. Connect Ground lead point A2 of human brain to the negative terminal (A2) of op-amp circuit.
STEP 2 : Click on check button to check for Correct Connections.
STEP 3 : If Connections are not correct click on reset button for reset connections.
STEP 4 : If Connections are correct click on play/pause button to see recorded eeg signals for Fp1 and Fp2.
STEP 5 : Click on waveform tab for data obsevation and measurement.
STEP 6 : Click on print button to save the observations.
4. For Central Lobe
STEP 1 : Make all the Correct Connections.
1. Connect C3 lead point of human brain to the positive terminal (C3) of first op-amp circuit.
2. Connect Cz lead point of human brain to the positive terminal (Cz) of second op-amp circuit.
3. Connect C4 lead point of human brain to the positive terminal (C4) of third op-amp circuit.
4. Connect Ground lead point A1 of human brain to the negative terminal (A1) of op-amp circuit.
5. Connect Ground lead point A2 of human brain to the negative terminal (A2) of op-amp circuit.
STEP 2 : Click on check button to check for Correct Connections.
STEP 3 : If Connections are not correct click on reset button for reset connections.
STEP 4 : If Connections are correct click on play/pause button to see recorded eeg signals for Fp1 and Fp2.
STEP 5 : Click on waveform tab for data obsevation and measurement.
STEP 6 : Click on print button to save the observations.
5. For Parietal Lobe
STEP 1 : Make all the Correct Connections.
1. Connect P3 lead point of human brain to the positive terminal (P3) of first op-amp circuit.
2. Connect Pz lead point of human brain to the positive terminal (Pz) of second op-amp circuit.
3. Connect P4 lead point of human brain to the positive terminal (P4) of third op-amp circuit.
4. Connect Ground lead point A1 of human brain to the negative terminal (A1) of op-amp circuit.
5. Connect Ground lead point A2 of human brain to the negative terminal (A2) of op-amp circuit.
STEP 2 : Click on check button to check for Correct Connections.
STEP 3 : If Connections are not correct click on reset button for reset connections.
STEP 4 : If Connections are correct click on play/pause button to see recorded eeg signals for Fp1 and Fp2.
STEP 5 : Click on waveform tab for data obsevation and measurement.
STEP 6 : Click on print button to save the observations.
6. For Occipital Lobe
STEP 1 : Make all the Correct Connections.
1. Connect O1 lead point of human brain to the positive terminal (O1) of first op-amp circuit.
2. Connect O2 lead point of human brain to the positive terminal (O2) of second op-amp circuit.
3. Connect Ground lead point A1 of human brain to the negative terminal (A1) of op-amp circuit.
4. Connect Ground lead point A2 of human brain to the negative terminal (A2) of op-amp circuit.
STEP 2 : Click on check button to check for Correct Connections.
STEP 3 : If Connections are not correct click on reset button for reset connections.
STEP 4 : If Connections are correct click on play/pause button to see recorded eeg signals for Fp1 and Fp2.
STEP 5 : Click on waveform tab for data obsevation and measurement.
STEP 6 : Click on print button to save the observations.